¿Cómo afecta la reutilización de limas tipo glide path su resistencia a la fatiga cíclica?
El objetivo de este estudio fue comparar la resistencia a la fatiga cíclica (CFR en inglés) de las limas PathFile (Dentsply Sirona, Ballaigues, Suiza) y ScoutRace (FKG Dentaire, La Chaux-de-Fonds, Suiza) de tipo glide path, nuevas o ya previamente utilizadas. Para este estudio se utilizaron 40 inst...
Main Authors: | , |
---|---|
Format: | Online |
Language: | eng |
Published: |
Universidad de Costa Rica
2021
|
Online Access: | https://revistas.ucr.ac.cr/index.php/Odontos/article/view/47503 |
id |
ODONTOS47503 |
---|---|
record_format |
ojs |
institution |
Universidad de Costa Rica |
collection |
Odovtos International Journal of Dental Sciences |
language |
eng |
format |
Online |
author |
Arıcan, Burçin Atav Ateş, Ayfer |
spellingShingle |
Arıcan, Burçin Atav Ateş, Ayfer ¿Cómo afecta la reutilización de limas tipo glide path su resistencia a la fatiga cíclica? |
author_facet |
Arıcan, Burçin Atav Ateş, Ayfer |
author_sort |
Arıcan, Burçin |
description |
El objetivo de este estudio fue comparar la resistencia a la fatiga cíclica (CFR en inglés) de las limas PathFile (Dentsply Sirona, Ballaigues, Suiza) y ScoutRace (FKG Dentaire, La Chaux-de-Fonds, Suiza) de tipo glide path, nuevas o ya previamente utilizadas. Para este estudio se utilizaron 40 instrumentos PathFile (PF) 19/.02 y 40 ScoutRace (SR) 20/.02. La mitad de las limas de cada grupo se utilizaron (PF-U y SR-U) en los modelos dentales de demostración 3D (FKG Dentaire, La Chaux-de-Fonds, Suiza) para crear trayectorias de deslizamiento, mientras que la otra mitad se utilizaron nuevas directamente a la prueba de fatiga cíclica (PF-N y SR-N). Las limas nuevas y usadas (n=80) se hicieron girar en el dispositivo de prueba de fatiga cíclica con un canal artificial de acero inoxidable (curvatura de 60°, radio de 5mm, anchura de 1,5mm y profundidad de 3,0mm) bajo irrigación continua con agua destilada a 37°C hasta que se produjo la fractura. Se registró el tiempo hasta la fractura y se realizó el análisis de fiabilidad de Weibull. Los datos se analizaron estadísticamente. La conformidad con la distribución normal se examinó mediante la prueba de Shapiro-Wilk. Se utilizó una prueba t de dos muestras pareadas para comparar los valores de TTF según el tiempo dentro de los grupos. Los instrumentos nuevos (PF-N y SR-N) mostraron una mejor CFR que los grupos previamente utilizados (PF-U y SR-U) (p<0,05). Los valores de TTF de PF fueron estadísticamente superiores a los de SR tanto en los grupos nuevos como en los usados (p<0,05). El tiempo previsto de supervivencia del 99% para las limas fue PF-N> SR-N >PF-U >SR-U. La reutilización de ambos instrumentos tipo glide path redujo el tiempo hasta la fractura y la resistencia a la fatiga cíclica de las limas. |
title |
¿Cómo afecta la reutilización de limas tipo glide path su resistencia a la fatiga cíclica? |
title_short |
¿Cómo afecta la reutilización de limas tipo glide path su resistencia a la fatiga cíclica? |
title_full |
¿Cómo afecta la reutilización de limas tipo glide path su resistencia a la fatiga cíclica? |
title_fullStr |
¿Cómo afecta la reutilización de limas tipo glide path su resistencia a la fatiga cíclica? |
title_full_unstemmed |
¿Cómo afecta la reutilización de limas tipo glide path su resistencia a la fatiga cíclica? |
title_sort |
¿cómo afecta la reutilización de limas tipo glide path su resistencia a la fatiga cíclica? |
title_alt |
How do Reused Glide Path Files Affect the Cyclic Fatigue Resistance? |
publisher |
Universidad de Costa Rica |
publishDate |
2021 |
url |
https://revistas.ucr.ac.cr/index.php/Odontos/article/view/47503 |
work_keys_str_mv |
AT arıcanburcin howdoreusedglidepathfilesaffectthecyclicfatigueresistance AT atavatesayfer howdoreusedglidepathfilesaffectthecyclicfatigueresistance AT arıcanburcin comoafectalareutilizaciondelimastipoglidepathsuresistenciaalafatigaciclica AT atavatesayfer comoafectalareutilizaciondelimastipoglidepathsuresistenciaalafatigaciclica |
_version_ |
1810113450976739328 |
spelling |
ODONTOS475032021-08-30T18:15:31Z How do Reused Glide Path Files Affect the Cyclic Fatigue Resistance? ¿Cómo afecta la reutilización de limas tipo glide path su resistencia a la fatiga cíclica? Arıcan, Burçin Atav Ateş, Ayfer Cyclic fatigue resistance; Demo model; Glide path; PathFile; Reuse; ScoutRace. Resistencia a la fatiga cíclica; Modelo de demostración; Trayectoria de deslizamiento; PathFile; Reutilización; ScoutRace. The aim of this study was to compare the cyclic fatigue resistance (CFR) of PathFile (Dentsply Sirona, Ballaigues, Switzerland) and ScoutRace (FKG Dentaire, La Chaux-de-Fonds, Switzerland) glide path files which were either new or previously used. Forty PathFile (PF) 19/.02 and 40 ScoutRace (SR) 20/.02 instruments were used for this study. Half of the files in each group were used (PF-U and SR-U) in the 3D demo tooth models (FKG Dentaire, La Chaux-de-Fonds, Switzerland) for creating glide paths, while the other half was new (PF-N and SR-N) and directly subjected to the cyclic fatigue test. The new and used files (n=80) were rotated in the cyclic fatigue test device with an artificial stainless-steel canal (60° curvature, 5 mm radius 1.5 mm width and 3.0 mm depth) under the continuous irrigation with distilled water at 37°C until fracture occurred. Time to fracture was recorded and the Weibull reliability analysis was performed. Data were statistically analysed. Conformity to normal distribution was examined using the Shapiro-Wilk test. A paired two-sample t-test was used to compare the TTF values according to the time within the groups. The new instruments (PF-N and SR-N) showed better CFR than the used groups (PF-U and SR-U) (P<0.05). The TTF values of PF were statistically higher than SR in both new and used groups (P<0.05). The predicted time for %99 survival for the files was PF-N> SR-N>PF-U >SR-U. Reuse of both glide path instruments reduced the time to fracture and the cyclic fatigue resistance of the files. El objetivo de este estudio fue comparar la resistencia a la fatiga cíclica (CFR en inglés) de las limas PathFile (Dentsply Sirona, Ballaigues, Suiza) y ScoutRace (FKG Dentaire, La Chaux-de-Fonds, Suiza) de tipo glide path, nuevas o ya previamente utilizadas. Para este estudio se utilizaron 40 instrumentos PathFile (PF) 19/.02 y 40 ScoutRace (SR) 20/.02. La mitad de las limas de cada grupo se utilizaron (PF-U y SR-U) en los modelos dentales de demostración 3D (FKG Dentaire, La Chaux-de-Fonds, Suiza) para crear trayectorias de deslizamiento, mientras que la otra mitad se utilizaron nuevas directamente a la prueba de fatiga cíclica (PF-N y SR-N). Las limas nuevas y usadas (n=80) se hicieron girar en el dispositivo de prueba de fatiga cíclica con un canal artificial de acero inoxidable (curvatura de 60°, radio de 5mm, anchura de 1,5mm y profundidad de 3,0mm) bajo irrigación continua con agua destilada a 37°C hasta que se produjo la fractura. Se registró el tiempo hasta la fractura y se realizó el análisis de fiabilidad de Weibull. Los datos se analizaron estadísticamente. La conformidad con la distribución normal se examinó mediante la prueba de Shapiro-Wilk. Se utilizó una prueba t de dos muestras pareadas para comparar los valores de TTF según el tiempo dentro de los grupos. Los instrumentos nuevos (PF-N y SR-N) mostraron una mejor CFR que los grupos previamente utilizados (PF-U y SR-U) (p<0,05). Los valores de TTF de PF fueron estadísticamente superiores a los de SR tanto en los grupos nuevos como en los usados (p<0,05). El tiempo previsto de supervivencia del 99% para las limas fue PF-N> SR-N >PF-U >SR-U. La reutilización de ambos instrumentos tipo glide path redujo el tiempo hasta la fractura y la resistencia a la fatiga cíclica de las limas. Universidad de Costa Rica 2021-06-21 info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Article application/pdf text/html application/epub+zip https://revistas.ucr.ac.cr/index.php/Odontos/article/view/47503 10.15517/ijds.2021.47503 Odovtos - International Journal of Dental Sciences; Vol. 23 No. 3 (2021): Odovtos-International Journal of Dental Sciences; 98-106 Odovtos International Journal of Dental Sciences; Vol. 23 Núm. 3 (2021): Odovtos-International Journal of Dental Sciences; 98-106 2215-3411 1659-1046 10.15517/ijds.2021 eng https://revistas.ucr.ac.cr/index.php/Odontos/article/view/47503/46932 https://revistas.ucr.ac.cr/index.php/Odontos/article/view/47503/46933 https://revistas.ucr.ac.cr/index.php/Odontos/article/view/47503/46934 |