Análisis multielemental de material foliar por medio de ICP-MS.

Se desarrolló un método analítico que permite la aplicación de la técnica híbrida “ICP MS” en el análisis multielemental simultáneo de tejidos foliares. Se optimizó el tratamiento del material foliar, el cual consistió en digerir aproximadamente 0,38 g del tejido foliar, previamente secado y tamizad...

Descripción completa

Detalles Bibliográficos
Autores principales: Alvarado1, Ana Lorena, Yglesias, José Miguel, Güell, Oscar
Formato: Online
Idioma:spa
Publicado: Universidad de Costa Rica 2005
Acceso en línea:https://revistas.ucr.ac.cr/index.php/agrocost/article/view/60178
id AGROCOST60178
record_format ojs
institution Universidad de Costa Rica
collection Agronomia Costarricense
language spa
format Online
author Alvarado1, Ana Lorena
Yglesias, José Miguel
Güell, Oscar
spellingShingle Alvarado1, Ana Lorena
Yglesias, José Miguel
Güell, Oscar
Análisis multielemental de material foliar por medio de ICP-MS.
author_facet Alvarado1, Ana Lorena
Yglesias, José Miguel
Güell, Oscar
author_sort Alvarado1, Ana Lorena
description Se desarrolló un método analítico que permite la aplicación de la técnica híbrida “ICP MS” en el análisis multielemental simultáneo de tejidos foliares. Se optimizó el tratamiento del material foliar, el cual consistió en digerir aproximadamente 0,38 g del tejido foliar, previamente secado y tamizado a 0,5 mm, con HNO3 concentrado; al digerido así obtenido, se le agregó Telurio como estándar interno y luego se diluyó con agua desionizada. La cuantificación se llevó a cabo mediante un ICP-MS ELAN 6000 de PE-Sciex, bajo condiciones instrumen tales recomendadas en la literatura y algunas obtenidas mediante procesos de optimización. Los parámetros del desempeño analítico fueron satisfactorios para los siguientes elementos: Al, As, Be, Cd, Co, Cr, Cu, Fe, Li, Mg, Mn, Mo, Na, Ni, P, Pb, Sb, Se, Tl, V y Zn. Sus límites de detección se calcularon mediante 2 procedimientos diferentes, y oscilaron entre 1 μg l-1 para el Cd y 40 μg l-1 para el P. La exactitud de la metodología propuesta se evaluó determinando los porcentajes de recuperación a 3 niveles de concentración diferentes y empleando además una muestra con contenidos certificados para algunos de los elementos. Los resultados de ambos ensayos incluyeron recuperaciones ubicadas entre un 82% para el Mg y 140% para el Zn. Las sensibilidades promedio se encontraron entre 157 cps (μg l-1)-1 para el Be y 12272 cps (μg l-1)-1 para el Tl. La precisión del método, expresada mediante la desviación estándar relativa, abarcó desde un 0,8% para el As hasta un 18,6% para el Zn. Se comprobó también que las respuestas obtenidas para cada elemento presentaron un comportamiento lineal en el ámbito de concentraciones de interés.
title Análisis multielemental de material foliar por medio de ICP-MS.
title_short Análisis multielemental de material foliar por medio de ICP-MS.
title_full Análisis multielemental de material foliar por medio de ICP-MS.
title_fullStr Análisis multielemental de material foliar por medio de ICP-MS.
title_full_unstemmed Análisis multielemental de material foliar por medio de ICP-MS.
title_sort análisis multielemental de material foliar por medio de icp-ms.
title_alt Multielemental analysis of foliar tissue using ICP-MS
publisher Universidad de Costa Rica
publishDate 2005
url https://revistas.ucr.ac.cr/index.php/agrocost/article/view/60178
work_keys_str_mv AT alvarado1analorena multielementalanalysisoffoliartissueusingicpms
AT yglesiasjosemiguel multielementalanalysisoffoliartissueusingicpms
AT guelloscar multielementalanalysisoffoliartissueusingicpms
AT alvarado1analorena analisismultielementaldematerialfoliarpormediodeicpms
AT yglesiasjosemiguel analisismultielementaldematerialfoliarpormediodeicpms
AT guelloscar analisismultielementaldematerialfoliarpormediodeicpms
_version_ 1822054295650959360
spelling AGROCOST601782024-08-30T17:28:49Z Multielemental analysis of foliar tissue using ICP-MS Análisis multielemental de material foliar por medio de ICP-MS. Alvarado1, Ana Lorena Yglesias, José Miguel Güell, Oscar multielemental analysis foliar material inductively coupled plasma mass detector validation análisis multielemental material foliar plasma inducido detector de masas validación An analytical method that allows the applicability of the hybrid technique ICP-MS to simultaneous multielemental analysis for foliar tissues was developed. The sample treatment, was optimized by digesting approximately 0.38 g of the foliar tissue, previously dried and screened to 0.5 mm mesh, with concentrated HNO3 until a clear product was obtained, after dilution with deionized water. Te was added as an internal standard. The quantification was done with an ICP-MS ELAN 6000, from PE-Sciex, under recommended instrumental conditions from the literature and other conditions optimized in the laboratory. The analytical performance parameters were satisfactory for the following elements: Al, As, Be, Cd, Co, Cr, Cu, Fe, Li, Mg, Mn, Mo, Na, Ni, P, Pb, Sb, Se, Tl, V and Zn. The detection limits were calculated by 2 methods, and they ranged between 1 μg l-1 for Cd and 40 μg l-1 for P. The accuracy of the proposed methodology was evaluated by determining the recovery percentage at 3 different concentration levels, also with a matrix with certified contents for some elements. Results from both assays included recoveries between 82% for Mg and 140% for Zn. The average values of sensibilities ranged from 157 cps (μg l-1)-1 for Be to 12272 cps (μg l-1)-1 for Tl. The precision of the method, as expressed by means of the relative standard deviation, was from 0.8% for As to 18.6% for Zn. It was shown also that results obtained for each element presented a linear behavior in the range of concentrations concerned. Se desarrolló un método analítico que permite la aplicación de la técnica híbrida “ICP MS” en el análisis multielemental simultáneo de tejidos foliares. Se optimizó el tratamiento del material foliar, el cual consistió en digerir aproximadamente 0,38 g del tejido foliar, previamente secado y tamizado a 0,5 mm, con HNO3 concentrado; al digerido así obtenido, se le agregó Telurio como estándar interno y luego se diluyó con agua desionizada. La cuantificación se llevó a cabo mediante un ICP-MS ELAN 6000 de PE-Sciex, bajo condiciones instrumen tales recomendadas en la literatura y algunas obtenidas mediante procesos de optimización. Los parámetros del desempeño analítico fueron satisfactorios para los siguientes elementos: Al, As, Be, Cd, Co, Cr, Cu, Fe, Li, Mg, Mn, Mo, Na, Ni, P, Pb, Sb, Se, Tl, V y Zn. Sus límites de detección se calcularon mediante 2 procedimientos diferentes, y oscilaron entre 1 μg l-1 para el Cd y 40 μg l-1 para el P. La exactitud de la metodología propuesta se evaluó determinando los porcentajes de recuperación a 3 niveles de concentración diferentes y empleando además una muestra con contenidos certificados para algunos de los elementos. Los resultados de ambos ensayos incluyeron recuperaciones ubicadas entre un 82% para el Mg y 140% para el Zn. Las sensibilidades promedio se encontraron entre 157 cps (μg l-1)-1 para el Be y 12272 cps (μg l-1)-1 para el Tl. La precisión del método, expresada mediante la desviación estándar relativa, abarcó desde un 0,8% para el As hasta un 18,6% para el Zn. Se comprobó también que las respuestas obtenidas para cada elemento presentaron un comportamiento lineal en el ámbito de concentraciones de interés. Universidad de Costa Rica 2005-01-01 info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Article Artículo application/pdf https://revistas.ucr.ac.cr/index.php/agrocost/article/view/60178 10.15517/rac.v29i1.60178 Agronomía Costarricense; Agronomía Costarricense: Vol. 29, Issue 1 (January-June); 17-27 Agronomía Costarricense; Agronomía Costarricense: Vol. 29, Nº 1 (Enero-Junio); 17-27 2215-2202 0377-9424 10.15517/rac.v29i1 spa https://revistas.ucr.ac.cr/index.php/agrocost/article/view/60178/60035 Derechos de autor 2024 Agronomía Costarricense https://creativecommons.org/licenses/by-nc-nd/4.0