Nivel óseo alrededor de implantes adyacentes a dientes e implantes

[Objetivo] Determinar las diferencias en el nivel óseo de implantes adyacentes a dientes e implantes. [Metodología] en este estudio transversal se incluyeron 17 pacientes con un total de 51 implantes dentales estables con carga funcional de, al menos, 6 meses. Los implantes estaban localizados adyac...

Descripción completa

Detalles Bibliográficos
Autores principales: Gómez-Guzmán, John Jairo, Arias-Holguín, Yohana Marcela, Pérez, María Isabel, Restrepo-Restrepo, Felipe Augusto, Rodríguez-Medina, Carolina, Botero, Javier Enrique
Formato: Online
Idioma:spa
Publicado: Universidad Nacional, Costa Rica 2022
Acceso en línea:https://www.revistas.una.ac.cr/index.php/uniciencia/article/view/16519
id UNICIENCIA16519
record_format ojs
institution Universidad Nacional de Costa Rica
collection Uniciencia
language spa
format Online
author Gómez-Guzmán, John Jairo
Arias-Holguín, Yohana Marcela
Pérez, María Isabel
Restrepo-Restrepo, Felipe Augusto
Rodríguez-Medina, Carolina
Botero, Javier Enrique
spellingShingle Gómez-Guzmán, John Jairo
Arias-Holguín, Yohana Marcela
Pérez, María Isabel
Restrepo-Restrepo, Felipe Augusto
Rodríguez-Medina, Carolina
Botero, Javier Enrique
Nivel óseo alrededor de implantes adyacentes a dientes e implantes
author_facet Gómez-Guzmán, John Jairo
Arias-Holguín, Yohana Marcela
Pérez, María Isabel
Restrepo-Restrepo, Felipe Augusto
Rodríguez-Medina, Carolina
Botero, Javier Enrique
author_sort Gómez-Guzmán, John Jairo
description [Objetivo] Determinar las diferencias en el nivel óseo de implantes adyacentes a dientes e implantes. [Metodología] en este estudio transversal se incluyeron 17 pacientes con un total de 51 implantes dentales estables con carga funcional de, al menos, 6 meses. Los implantes estaban localizados adyacentes a dientes naturales/implantes o ambos. Se realizó análisis clínico completo de los implantes y dientes adyacentes, así como medición radiográfica del nivel óseo adyacente a diente o implante. Los datos fueron analizados para determinar diferencias en el nivel óseo del lado adyacente a diente en comparación con el lado adyacente a implante (p ≤ 0.05). [Resultados] La distancia de la cresta ósea en sentido coronal a la plataforma del implante, en relación con la presencia de diente o implante fue alrededor de 1 mm. El nivel óseo en zonas adyacentes a implantes se localizó más apical (2.9 ± 1.4 mm) en comparación con zonas adyacentes a dientes naturales (1.3 ± 0.07 mm; p < 0.05). El análisis bivariado indicó que es más probable encontrar el nivel óseo más coronal a la plataforma de un implante adyacente a diente, en comparación con la presencia de otro implante adyacente (p = 0.04). [Conclusión] los resultados de este estudio indican que el nivel óseo de implantes adyacentes a dientes naturales se mantiene más coronal a la plataforma del implante en comparación con las zonas adyacentes a otros implantes. Esto sugiere mayor estabilidad de implantes cuando están adyacentes a dientes naturales.
title Nivel óseo alrededor de implantes adyacentes a dientes e implantes
title_short Nivel óseo alrededor de implantes adyacentes a dientes e implantes
title_full Nivel óseo alrededor de implantes adyacentes a dientes e implantes
title_fullStr Nivel óseo alrededor de implantes adyacentes a dientes e implantes
title_full_unstemmed Nivel óseo alrededor de implantes adyacentes a dientes e implantes
title_sort nivel óseo alrededor de implantes adyacentes a dientes e implantes
title_alt Bone level around dental implants adjacent to teeth and implants
Nível ósseo ao redor de implantes adjacentes a dentes e implantes
publisher Universidad Nacional, Costa Rica
publishDate 2022
url https://www.revistas.una.ac.cr/index.php/uniciencia/article/view/16519
work_keys_str_mv AT gomezguzmanjohnjairo bonelevelarounddentalimplantsadjacenttoteethandimplants
AT ariasholguinyohanamarcela bonelevelarounddentalimplantsadjacenttoteethandimplants
AT perezmariaisabel bonelevelarounddentalimplantsadjacenttoteethandimplants
AT restreporestrepofelipeaugusto bonelevelarounddentalimplantsadjacenttoteethandimplants
AT rodriguezmedinacarolina bonelevelarounddentalimplantsadjacenttoteethandimplants
AT boterojavierenrique bonelevelarounddentalimplantsadjacenttoteethandimplants
AT gomezguzmanjohnjairo niveloseoalrededordeimplantesadyacentesadienteseimplantes
AT ariasholguinyohanamarcela niveloseoalrededordeimplantesadyacentesadienteseimplantes
AT perezmariaisabel niveloseoalrededordeimplantesadyacentesadienteseimplantes
AT restreporestrepofelipeaugusto niveloseoalrededordeimplantesadyacentesadienteseimplantes
AT rodriguezmedinacarolina niveloseoalrededordeimplantesadyacentesadienteseimplantes
AT boterojavierenrique niveloseoalrededordeimplantesadyacentesadienteseimplantes
AT gomezguzmanjohnjairo nivelosseoaoredordeimplantesadjacentesadenteseimplantes
AT ariasholguinyohanamarcela nivelosseoaoredordeimplantesadjacentesadenteseimplantes
AT perezmariaisabel nivelosseoaoredordeimplantesadjacentesadenteseimplantes
AT restreporestrepofelipeaugusto nivelosseoaoredordeimplantesadjacentesadenteseimplantes
AT rodriguezmedinacarolina nivelosseoaoredordeimplantesadjacentesadenteseimplantes
AT boterojavierenrique nivelosseoaoredordeimplantesadjacentesadenteseimplantes
_version_ 1782035766092759040
spelling UNICIENCIA165192022-06-14T15:37:27Z Bone level around dental implants adjacent to teeth and implants Nivel óseo alrededor de implantes adyacentes a dientes e implantes Nível ósseo ao redor de implantes adjacentes a dentes e implantes Gómez-Guzmán, John Jairo Arias-Holguín, Yohana Marcela Pérez, María Isabel Restrepo-Restrepo, Felipe Augusto Rodríguez-Medina, Carolina Botero, Javier Enrique [Objective] This investigation seeks to determine the difference in bone level around implants adjacent to teeth and implants. [Methodology] This cross-sectional study included 17 patients with a total of 51 stable implants with a functional loading of at least 6 months. These implants were located next to natural teeth, other implants, or both. All implants and adjacent teeth were clinically examined, and periodontal and peri-implant parameters were recorded. A radiographic analysis was carried out to measure the bone level around implants in relation to the implant platform. Data were analyzed to detect differences between bone levels on the side of an implant next to a tooth compared to those on the side of an implant next to another implant. Statistical differences were considered significant when p≤0.05. [Results] The distance from the crestal bone on the coronal side of the implant platform to adjacent teeth or implants was approximately 1 mm. The bone level in zones adjacent to other implants was more apically located (2.9 ± 1.4 mm) than was the case for bone levels on sides adjacent to natural teeth (1.3 ± 0.07 mm) and the difference in these distances was statistically significant (p<0.05). Bivariate analysis showed that the bone level around implants was more likely to be coronal in relation to the implant platform on the side adjacent to a tooth than on the side adjacent to another implant (p=0.04). [Conclusions] The results indicate that the bone level of implants adjacent to natural teeth is maintained more coronal as compared to implants adjacent to other implants. This suggests a greater stability of implants when they are located near remaining natural teeth. [Objetivo] Determinar las diferencias en el nivel óseo de implantes adyacentes a dientes e implantes. [Metodología] en este estudio transversal se incluyeron 17 pacientes con un total de 51 implantes dentales estables con carga funcional de, al menos, 6 meses. Los implantes estaban localizados adyacentes a dientes naturales/implantes o ambos. Se realizó análisis clínico completo de los implantes y dientes adyacentes, así como medición radiográfica del nivel óseo adyacente a diente o implante. Los datos fueron analizados para determinar diferencias en el nivel óseo del lado adyacente a diente en comparación con el lado adyacente a implante (p ≤ 0.05). [Resultados] La distancia de la cresta ósea en sentido coronal a la plataforma del implante, en relación con la presencia de diente o implante fue alrededor de 1 mm. El nivel óseo en zonas adyacentes a implantes se localizó más apical (2.9 ± 1.4 mm) en comparación con zonas adyacentes a dientes naturales (1.3 ± 0.07 mm; p < 0.05). El análisis bivariado indicó que es más probable encontrar el nivel óseo más coronal a la plataforma de un implante adyacente a diente, en comparación con la presencia de otro implante adyacente (p = 0.04). [Conclusión] los resultados de este estudio indican que el nivel óseo de implantes adyacentes a dientes naturales se mantiene más coronal a la plataforma del implante en comparación con las zonas adyacentes a otros implantes. Esto sugiere mayor estabilidad de implantes cuando están adyacentes a dientes naturales. [Objetivo] Determinar as diferenças no nível ósseo dos implantes adjacentes a dentes e implantes. [Metodologia] este estudo transversal incluiu 17 pacientes com um total de 51 implantes dentários estáveis com carga funcional de pelo menos 6 meses. Os implantes foram localizados adjacentes a dentes/implantes naturais ou ambos. Foi realizada uma análise clínica completa dos implantes e dentes adjacentes, bem como a medição radiográfica do nível ósseo adjacente ao dente ou implante. Os dados foram analisados para determinar diferenças no nível ósseo no lado adjacente ao dente em comparação com o lado adjacente ao implante (p ≤ 0,05). [Resultados] A distância da crista óssea na direção coronal até a plataforma de implante, em relação à presença de um dente ou implante, foi de cerca de 1 mm. O nível ósseo em áreas adjacentes aos implantes foi mais apical (2,9 ± 1,4 mm) em comparação com áreas adjacentes aos dentes naturais (1,3 ± 0,07 mm; p < 0,05). A análise bivariada indicou que é mais provável encontrar o nível ósseo mais coronal na plataforma de um implante adjacente a um dente, em comparação com a presença de outro implante adjacente (p = 0,04). [Conclusão] os resultados deste estudo indicam que o nível ósseo de implantes adjacentes aos dentes naturais permanece mais coronal à plataforma de implante em comparação com áreas adjacentes a outros implantes. Sugerindo, portanto, maior estabilidade dos implantes quando estão adjacentes aos dentes naturais. Universidad Nacional, Costa Rica 2022-01-31 info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Papers evaluated by academic peers Artículos evaluados por pares académicos application/pdf text/html application/epub+zip https://www.revistas.una.ac.cr/index.php/uniciencia/article/view/16519 10.15359/ru.36-1.13 Uniciencia; Vol 36 No 1 (2022): Uniciencia. January-December, 2022; 1-11 Uniciencia; Vol. 36 Núm. 1 (2022): Uniciencia. January-December, 2022; 1-11 Uniciencia; v. 36 n. 1 (2022): Uniciencia. January-December, 2022; 1-11 2215-3470 spa https://www.revistas.una.ac.cr/index.php/uniciencia/article/view/16519/24041 https://www.revistas.una.ac.cr/index.php/uniciencia/article/view/16519/24710 https://www.revistas.una.ac.cr/index.php/uniciencia/article/view/16519/24711 Copyright (c) 2022 Shared by Journal and Authors (CC-BY-NC-ND) http://creativecommons.org/licenses/by-nc-nd/4.0