Medición del gasto energético real por usar un producto comercial para ejercitarse en el hogar

La evidencia sobre la importancia de ejercitarse regularmente es abrumadora. Muchas personas, conscientes de ello, recurren a las soluciones simples y atractivas que se les venden por televisión. Lamentablemente, muchos países no tienen reglamentación estricta para valorar las afirmaciones que hacen...

Descripción completa

Detalles Bibliográficos
Autores principales: Montoya Arroyo, Jhonny Alberto, Ramírez Cambronero, Jimena, Aragón Vargas, Luis Fernando
Formato: Online
Idioma:spa
Publicado: Escuela de Educación Física y Deportes - Universidad de Costa Rica 2021
Acceso en línea:https://revistas.ucr.ac.cr/index.php/pem/article/view/40646
id PEM40646
record_format ojs
institution Universidad de Costa Rica
collection Pensar en Movimiento
language spa
format Online
author Montoya Arroyo, Jhonny Alberto
Ramírez Cambronero, Jimena
Aragón Vargas, Luis Fernando
spellingShingle Montoya Arroyo, Jhonny Alberto
Ramírez Cambronero, Jimena
Aragón Vargas, Luis Fernando
Medición del gasto energético real por usar un producto comercial para ejercitarse en el hogar
author_facet Montoya Arroyo, Jhonny Alberto
Ramírez Cambronero, Jimena
Aragón Vargas, Luis Fernando
author_sort Montoya Arroyo, Jhonny Alberto
description La evidencia sobre la importancia de ejercitarse regularmente es abrumadora. Muchas personas, conscientes de ello, recurren a las soluciones simples y atractivas que se les venden por televisión. Lamentablemente, muchos países no tienen reglamentación estricta para valorar las afirmaciones que hacen los productos comerciales; más aún, los requisitos para la evaluación científica de los productos relacionados con el ejercicio parecieran no existir. Cada vez que una persona compra un equipo para ejercitarse y poco después decide renunciar al ejercicio por la falta de resultados positivos, se da un paso hacia atrás en la salud pública. El propósito de este estudio fue medir el gasto energético inducido por utilizar un artículo comercialmente disponible para ejercitarse en casa y contrastarla con su publicidad. Se utilizaron distintos métodos de campo y laboratorio para medir el gasto energético de 27 estudiantes jóvenes, aparentemente saludables (15F, 12M; 19.1 ± 1.0 años; 1.647 ± .073 m; 63.09 ± 10.13 kg; M ± DT) mientras descansaban en posición decúbito supino durante diez minutos y mientras utilizaban la máquina para ejercitarse 10 minutos a intensidad intermedia. Ninguno de los métodos utilizados registró un gasto energético bruto superior a 272 kJ (65 kcal) en 10 min de actividad; el consumo de oxígeno durante el esfuerzo fue equivalente a 1.54 ± .23 MET, que corresponden a 23.4 ± 9.2 kJ (5.6 ± 2.2 kcal) de gasto neto o 70.3 ± 11.7 kJ (16.8 ± 2.8 kcal) de gasto bruto. En contraste, el gasto energético bruto reportado en el comercial del producto es de 277 kcal (1159 kJ) para 10 min. En conclusión, el gasto energético neto real es 1/50 (dos centésimas) del gasto energético presentado en la publicidad.
title Medición del gasto energético real por usar un producto comercial para ejercitarse en el hogar
title_short Medición del gasto energético real por usar un producto comercial para ejercitarse en el hogar
title_full Medición del gasto energético real por usar un producto comercial para ejercitarse en el hogar
title_fullStr Medición del gasto energético real por usar un producto comercial para ejercitarse en el hogar
title_full_unstemmed Medición del gasto energético real por usar un producto comercial para ejercitarse en el hogar
title_sort medición del gasto energético real por usar un producto comercial para ejercitarse en el hogar
title_alt Measurement of actual energy expenditure when using a commercial device for exercising at home
Medição do gasto energético real ao usar um produto comercial para exercitar-se em casa
publisher Escuela de Educación Física y Deportes - Universidad de Costa Rica
publishDate 2021
url https://revistas.ucr.ac.cr/index.php/pem/article/view/40646
work_keys_str_mv AT montoyaarroyojhonnyalberto measurementofactualenergyexpenditurewhenusingacommercialdeviceforexercisingathome
AT ramirezcambronerojimena measurementofactualenergyexpenditurewhenusingacommercialdeviceforexercisingathome
AT aragonvargasluisfernando measurementofactualenergyexpenditurewhenusingacommercialdeviceforexercisingathome
AT montoyaarroyojhonnyalberto mediciondelgastoenergeticorealporusarunproductocomercialparaejercitarseenelhogar
AT ramirezcambronerojimena mediciondelgastoenergeticorealporusarunproductocomercialparaejercitarseenelhogar
AT aragonvargasluisfernando mediciondelgastoenergeticorealporusarunproductocomercialparaejercitarseenelhogar
AT montoyaarroyojhonnyalberto medicaodogastoenergeticorealaousarumprodutocomercialparaexercitarseemcasa
AT ramirezcambronerojimena medicaodogastoenergeticorealaousarumprodutocomercialparaexercitarseemcasa
AT aragonvargasluisfernando medicaodogastoenergeticorealaousarumprodutocomercialparaexercitarseemcasa
_version_ 1781397081343131648
spelling PEM406462021-06-09T22:40:31Z Measurement of actual energy expenditure when using a commercial device for exercising at home Medición del gasto energético real por usar un producto comercial para ejercitarse en el hogar Medição do gasto energético real ao usar um produto comercial para exercitar-se em casa Montoya Arroyo, Jhonny Alberto Ramírez Cambronero, Jimena Aragón Vargas, Luis Fernando energy expenditure oxygen consumption commercial devices excercise gasto energético consumo de oxígeno productos comerciales actividad física gasto energético consumo de oxigênio produtos comerciais atividade física The evidence on the importance of regular exercise is overwhelming. Awareness of this fact leads many people to resort to simple, attractive solutions marketed through TV. Many countries, unfortunately, lack strict regulations to assess the claims made by commercial items. Moreover, it would seem that requirements for scientific evaluation of exercise-related products do not exist at all. Every time someone purchases exercising equipment and shortly afterwards decides to give up working out because no positive results can be seen, one step backwards is taken in public health. The purpose of this study was to measure the actual energy expenditure induced by using a commercially available device for exercising at home and compare it to the claims made about it in advertising. Various field and laboratory methods were used to measure the energy expenditure of 27 young, apparently healthy students (15F, 12 M; 19.1 ± 1.0 years old; 1.647 ± .073 m; 63.09 ± 10.13 kg; mean ± SD) while they were resting for 10 minutes in supine position, and then while working out on the equipment at medium speed for 10 minutes. None of the methods used showed a gross energy expenditure above 272 kJ (65 kcal) in 10 min activity. Oxygen consumption during stress was equivalent to 1.54 ± .23 MET, corresponding to 23.4 ± 9.2 kJ (5.6 ± 2.2 kcal) net expenditure, or 70.3 ± 11.7 kJ (16.8 ± 2.8 kcal) gross expenditure. In contrast, the gross energy expenditure reported in the equipment’s commercial is 277 kcal (1159 kJ) for 10 min. In conclusion, the actual net energy expenditure is 1/50 (two hundredths) the energy expenditure being claimed in the advertisements. La evidencia sobre la importancia de ejercitarse regularmente es abrumadora. Muchas personas, conscientes de ello, recurren a las soluciones simples y atractivas que se les venden por televisión. Lamentablemente, muchos países no tienen reglamentación estricta para valorar las afirmaciones que hacen los productos comerciales; más aún, los requisitos para la evaluación científica de los productos relacionados con el ejercicio parecieran no existir. Cada vez que una persona compra un equipo para ejercitarse y poco después decide renunciar al ejercicio por la falta de resultados positivos, se da un paso hacia atrás en la salud pública. El propósito de este estudio fue medir el gasto energético inducido por utilizar un artículo comercialmente disponible para ejercitarse en casa y contrastarla con su publicidad. Se utilizaron distintos métodos de campo y laboratorio para medir el gasto energético de 27 estudiantes jóvenes, aparentemente saludables (15F, 12M; 19.1 ± 1.0 años; 1.647 ± .073 m; 63.09 ± 10.13 kg; M ± DT) mientras descansaban en posición decúbito supino durante diez minutos y mientras utilizaban la máquina para ejercitarse 10 minutos a intensidad intermedia. Ninguno de los métodos utilizados registró un gasto energético bruto superior a 272 kJ (65 kcal) en 10 min de actividad; el consumo de oxígeno durante el esfuerzo fue equivalente a 1.54 ± .23 MET, que corresponden a 23.4 ± 9.2 kJ (5.6 ± 2.2 kcal) de gasto neto o 70.3 ± 11.7 kJ (16.8 ± 2.8 kcal) de gasto bruto. En contraste, el gasto energético bruto reportado en el comercial del producto es de 277 kcal (1159 kJ) para 10 min. En conclusión, el gasto energético neto real es 1/50 (dos centésimas) del gasto energético presentado en la publicidad. A evidência sobre a importância da prática contínua do exercício físico é indiscutível. Muitas pessoas, conscientes disso, recorrem a soluções simples e atraentes vendidas pela televisão. Infelizmente, muitos países não têm regulamentações estritas para validar as afirmações que os produtos comerciais fazem; mais ainda, as exigências para a avaliação científica dos produtos relacionados com o exercício parecem não existir. Toda vez que uma pessoa compra um equipamento para se exercitar e pouco depois decide renunciar ao exercício pela falta de resultados positivos é um retrocesso para a saúde pública. Este estudo teve como propósito medir o gasto energético provocado pelo uso de um item comercialmente disponível para fazer exercício em casa e contrastá-lo com sua publicidade. Foram utilizados distintos métodos de campo e laboratório para medir o gasto energético de 27 estudantes jovens, aparentemente saudáveis (15F, 12M; 19,1 ± 1,0 anos; 1,647 ± 0,073 m; 63,09 ± 10,13 kg; M ± DT) enquanto descansavam na posição decúbito dorsal durante dez minutos e enquanto utilizavam a máquina para se exercitar por 10 minutos na intensidade média. Nenhum dos métodos utilizados registrou um gasto energético bruto superior a 272 kJ (65 kcal) em 10 min de atividade; o consumo de oxigênio durante o esforço foi equivalente a 1,54 ± 0,23 MET, correspondente a 23,4 ± 9,2 kJ (5,6 ± 2,2 kcal) de gasto líquido ou 70,3 ± 11,7 kJ (16,8 ± 2,8 kcal) de gasto bruto. Em contraste, o gasto energético bruto informado no comercial do produto é de 277 kcal (1159 kJ) para 10 min. Para concluir, o gasto energético líquido real é 1/50 (dois centésimos) do gasto energético apresentado na publicidade. Escuela de Educación Física y Deportes - Universidad de Costa Rica 2021-04-30 info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Peer-reviewed article Artículo con revisión por pares Artigo avaliado pelos pares application/pdf application/pdf text/xml application/zip https://revistas.ucr.ac.cr/index.php/pem/article/view/40646 10.15517/pensarmov.v19i1.40646 PENSAR EN MOVIMIENTO (Thinking in/about Motion); Vol. 19 No. 1 (2021): Pensar en Movimiento: Revista de Ciencias del Ejercicio y la Salud (Opens january 1st, closes june 30th); e40646 Pensar en Movimiento: Revista de Ciencias del Ejercicio y la Salud; Vol. 19 Núm. 1 (2021): Pensar en Movimiento: Revista de Ciencias del Ejercicio y la Salud (Abre 1° de enero, cierra 30 de junio); e40646 Pensar en movimiento; Vol. 19 N.º 1 (2021): Pensar en Movimiento: Revista de Ciencias del Ejercicio y la Salud (Abre 1° de enero, cierra 30 de junio); e40646 1659-4436 1409-0724 spa https://revistas.ucr.ac.cr/index.php/pem/article/view/40646/46356 https://revistas.ucr.ac.cr/index.php/pem/article/view/40646/46792 https://revistas.ucr.ac.cr/index.php/pem/article/view/40646/46821 https://revistas.ucr.ac.cr/index.php/pem/article/view/40646/46822 Derechos de autor 2021 Jhonny Alberto Montoya Arroyo, Jimena Ramírez Cambronero, Luis Fernando Aragón Vargas