Efecto de diferentes agentes descontaminantes sobre la resistencia de unión de bloques CAD/CAM y resinas compuestas

El propósito de este estudio fue examinar el efecto de diferentes agentes descontaminantes sobre la fuerza de unión de bloques CAD/CAM contaminados con saliva y materiales compuestos de reparación. Se prepararon doscientas ochenta muestras de 3 mm de espesor a partir de cuatro materiales CAD/CAM dif...

Descripción completa

Detalles Bibliográficos
Autores principales: Kopuz, Dilan, Sancak, Elif İlgi, Tekçe, Neslihan
Formato: Online
Idioma:eng
Publicado: Universidad de Costa Rica 2023
Acceso en línea:https://revistas.ucr.ac.cr/index.php/Odontos/article/view/56839
id ODONTOS56839
record_format ojs
institution Universidad de Costa Rica
collection Odovtos International Journal of Dental Sciences
language eng
format Online
author Kopuz, Dilan
Sancak, Elif İlgi
Tekçe, Neslihan
spellingShingle Kopuz, Dilan
Sancak, Elif İlgi
Tekçe, Neslihan
Efecto de diferentes agentes descontaminantes sobre la resistencia de unión de bloques CAD/CAM y resinas compuestas
author_facet Kopuz, Dilan
Sancak, Elif İlgi
Tekçe, Neslihan
author_sort Kopuz, Dilan
description El propósito de este estudio fue examinar el efecto de diferentes agentes descontaminantes sobre la fuerza de unión de bloques CAD/CAM contaminados con saliva y materiales compuestos de reparación. Se prepararon doscientas ochenta muestras de 3 mm de espesor a partir de cuatro materiales CAD/CAM diferentes: disco Katana Zirconia UTML, bloque IPS e.max CAD, bloque Shofu y bloque Vita Enamic. Cada material se dividió en siete subgrupos diferentes (N=70). El grupo 1 tenía una superficie limpia. Los otros grupos estaban compuestos por muestras que estaban contaminadas con saliva humana: grupo 2: control negativo (no limpio); grupo 3: limpiado con agua pulverizada; grupo 4: limpiado con etanol al 70%; grupo 5: limpiado con Ivoclean; grupo 6: limpiado con Katana Cleaner; y grupo 7: limpiado con ácido fosfórico. Después de los protocolos de descontaminación, los cilindros de composite de resina se adhirieron a las superficies CAD/CAM con una fina capa de cemento de resina de curado dual. Las muestras se almacenaron durante 24 horas a 37°C en agua destilada. Luego, fueron sometidos a una prueba de resistencia al corte (SBS). Se registraron los valores y se evaluaron los tipos de fracturas utilizando un microscopio. Los datos se analizaron mediante ANOVA de dos factores y la prueba post-hoc de Tukey. En general, todos los agentes descontaminantes mejoraron el SBS de los composites con los materiales Katana Zirconia UTML, IPS e.max y Vita Enamic (p<0,05). Sin embargo, para los materiales Shofu, las muestras del grupo 6 exhibieron valores de fuerza de unión significativamente más altos en comparación con las muestras del grupo 2 (p=0,026). Los valores más altos de SBS se observaron en el grupo tratado con ácido fosfórico en materiales de circonio Katana (26,45 ± 9,38 MPa), mientras que los valores más bajos se observaron en las muestras del grupo 2 en materiales Shofu (13,17 ± 3,40 MPa). Cada agente descontaminante mejoró la fuerza de unión de los composites a los materiales CAD/CAM contaminados. Si no se limpia la saliva antes del procedimiento adhesivo, los valores de SBS pueden disminuir. Todos los agentes descontaminantes se pueden utilizar de forma segura en superficies de circonio, cerámica de vidrio de disilicato de litio, cerámica híbrida y cerámica con infiltraciones de polímeros.
title Efecto de diferentes agentes descontaminantes sobre la resistencia de unión de bloques CAD/CAM y resinas compuestas
title_short Efecto de diferentes agentes descontaminantes sobre la resistencia de unión de bloques CAD/CAM y resinas compuestas
title_full Efecto de diferentes agentes descontaminantes sobre la resistencia de unión de bloques CAD/CAM y resinas compuestas
title_fullStr Efecto de diferentes agentes descontaminantes sobre la resistencia de unión de bloques CAD/CAM y resinas compuestas
title_full_unstemmed Efecto de diferentes agentes descontaminantes sobre la resistencia de unión de bloques CAD/CAM y resinas compuestas
title_sort efecto de diferentes agentes descontaminantes sobre la resistencia de unión de bloques cad/cam y resinas compuestas
title_alt Effect of Different Decontamination Agents on The Bond Strength of CAD/CAM Blocks and Repair Composite Materials
publisher Universidad de Costa Rica
publishDate 2023
url https://revistas.ucr.ac.cr/index.php/Odontos/article/view/56839
work_keys_str_mv AT kopuzdilan effectofdifferentdecontaminationagentsonthebondstrengthofcadcamblocksandrepaircompositematerials
AT sancakelifilgi effectofdifferentdecontaminationagentsonthebondstrengthofcadcamblocksandrepaircompositematerials
AT tekceneslihan effectofdifferentdecontaminationagentsonthebondstrengthofcadcamblocksandrepaircompositematerials
AT kopuzdilan efectodediferentesagentesdescontaminantessobrelaresistenciadeuniondebloquescadcamyresinascompuestas
AT sancakelifilgi efectodediferentesagentesdescontaminantessobrelaresistenciadeuniondebloquescadcamyresinascompuestas
AT tekceneslihan efectodediferentesagentesdescontaminantessobrelaresistenciadeuniondebloquescadcamyresinascompuestas
_version_ 1810113467693137920
spelling ODONTOS568392023-12-11T19:53:09Z Effect of Different Decontamination Agents on The Bond Strength of CAD/CAM Blocks and Repair Composite Materials Efecto de diferentes agentes descontaminantes sobre la resistencia de unión de bloques CAD/CAM y resinas compuestas Kopuz, Dilan Sancak, Elif İlgi Tekçe, Neslihan Ivoclean; Katana Cleaner; CAD/CAM; Surface decontamination; Shear bond strength; Composite. Ivoclean; Limpiador de katanas; CAD/CAM; Descontaminación de superficies; Resistencia al corte; Compuesto. The purpose of this study was to examine the effect of different decontamination agents on the bond strength of saliva-contaminated CAD/CAM blocks and repair composite materials. Two hunderd eighty 3-mm-thick specimens were prepared from four different CAD/CAM materials: Katana Zirconia UTML disc, IPS e.max CAD block, Shofu block, and Vita Enamic block. Each material was divided into seven different subgroups (N=70). Group 1 had a clean surface. The other groups were comprised of the samples, which were contaminated with human saliva: group 2: negative control (non-cleaned); group 3: cleaned with water spray; group 4: cleaned with 70% ethanol; group 5: cleaned with Ivoclean; group 6: cleaned with Katana Cleaner; and group 7: cleaned with phosphoric acid. After the decontamination protocols, the resin composite cylinders were bonded to the CAD/CAM surfaces with a thin layer of dual-cured resin cement. The samples were stored for 24 hours at 37°C  in distilled water. Then, they were subjected to a shear bond strength test (SBS). The values were recorded, and fracture types were evaluated using a microscope. Data were analyzed using two-way ANOVA and Tukey’s post-hoc test. Generally, all decontaminating agents improved the SBS of composites to Katana Zirconia UTML, IPS e.max, and Vita Enamic materials (p<0.05). However, for Shofu materials, group 6 samples exhibited significantly higher bond strength values as compared with group 2 samples (p=0.026). The highest SBS values were seen in the phosphoric acid-treated group in Katana zirconia materials (26.45 ± 9.38 MPa), whereas the lowest values were seen in group 2 samples in Shofu materials (13.17 ± 3.40 MPa). Each decontaminant agent improved the bond strength of composites to the contaminated CAD/CAM materials. If saliva is not cleaned before adhesive procedure, SBS values may decrease. All decontamination agents can be used safely on zirconia, lithium-disilicate glass-ceramic, hybrid ceramic, and polymer-infiltrated ceramic surfaces. El propósito de este estudio fue examinar el efecto de diferentes agentes descontaminantes sobre la fuerza de unión de bloques CAD/CAM contaminados con saliva y materiales compuestos de reparación. Se prepararon doscientas ochenta muestras de 3 mm de espesor a partir de cuatro materiales CAD/CAM diferentes: disco Katana Zirconia UTML, bloque IPS e.max CAD, bloque Shofu y bloque Vita Enamic. Cada material se dividió en siete subgrupos diferentes (N=70). El grupo 1 tenía una superficie limpia. Los otros grupos estaban compuestos por muestras que estaban contaminadas con saliva humana: grupo 2: control negativo (no limpio); grupo 3: limpiado con agua pulverizada; grupo 4: limpiado con etanol al 70%; grupo 5: limpiado con Ivoclean; grupo 6: limpiado con Katana Cleaner; y grupo 7: limpiado con ácido fosfórico. Después de los protocolos de descontaminación, los cilindros de composite de resina se adhirieron a las superficies CAD/CAM con una fina capa de cemento de resina de curado dual. Las muestras se almacenaron durante 24 horas a 37°C en agua destilada. Luego, fueron sometidos a una prueba de resistencia al corte (SBS). Se registraron los valores y se evaluaron los tipos de fracturas utilizando un microscopio. Los datos se analizaron mediante ANOVA de dos factores y la prueba post-hoc de Tukey. En general, todos los agentes descontaminantes mejoraron el SBS de los composites con los materiales Katana Zirconia UTML, IPS e.max y Vita Enamic (p<0,05). Sin embargo, para los materiales Shofu, las muestras del grupo 6 exhibieron valores de fuerza de unión significativamente más altos en comparación con las muestras del grupo 2 (p=0,026). Los valores más altos de SBS se observaron en el grupo tratado con ácido fosfórico en materiales de circonio Katana (26,45 ± 9,38 MPa), mientras que los valores más bajos se observaron en las muestras del grupo 2 en materiales Shofu (13,17 ± 3,40 MPa). Cada agente descontaminante mejoró la fuerza de unión de los composites a los materiales CAD/CAM contaminados. Si no se limpia la saliva antes del procedimiento adhesivo, los valores de SBS pueden disminuir. Todos los agentes descontaminantes se pueden utilizar de forma segura en superficies de circonio, cerámica de vidrio de disilicato de litio, cerámica híbrida y cerámica con infiltraciones de polímeros. Universidad de Costa Rica 2023-12-11 info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Article application/pdf text/html application/epub+zip https://revistas.ucr.ac.cr/index.php/Odontos/article/view/56839 10.15517/ijds.2023.56839 Odovtos - International Journal of Dental Sciences; Vol. 26 No. 1 (2024): (January-April) Odovtos-International Journal of Dental Sciences; 76-85 Odovtos International Journal of Dental Sciences; Vol. 26 Núm. 1 (2024): (January-April) Odovtos-International Journal of Dental Sciences; 76-85 2215-3411 1659-1046 10.15517/ijds.2024 eng https://revistas.ucr.ac.cr/index.php/Odontos/article/view/56839/57536 https://revistas.ucr.ac.cr/index.php/Odontos/article/view/56839/57537 https://revistas.ucr.ac.cr/index.php/Odontos/article/view/56839/57538 Copyright (c) 2023 CC-BY-NC-SA 4.0 https://creativecommons.org/licenses/by-nc-sa/4.0