Efecto in vitro de los limpiadores de prótesis en la estabilidad del color de la polieteretercetona y otros polímeros base de prótesis

El objetivo de este estudio in vitro fue comparar el efecto a largo plazo del uso nocturno de limpiadores de prótesis con diferentes composiciones químicas sobre la estabilidad del color de los polímeros base de prótesis (DBP). Los cuatro DBP evaluados fueron PEEK (grupo PK), poliamida moldeada por...

Descripción completa

Detalles Bibliográficos
Autor principal: Tekin, Samet
Formato: Online
Idioma:eng
Publicado: Universidad de Costa Rica 2021
Acceso en línea:https://revistas.ucr.ac.cr/index.php/Odontos/article/view/47335
id ODONTOS47335
record_format ojs
institution Universidad de Costa Rica
collection Odovtos International Journal of Dental Sciences
language eng
format Online
author Tekin, Samet
spellingShingle Tekin, Samet
Efecto in vitro de los limpiadores de prótesis en la estabilidad del color de la polieteretercetona y otros polímeros base de prótesis
author_facet Tekin, Samet
author_sort Tekin, Samet
description El objetivo de este estudio in vitro fue comparar el efecto a largo plazo del uso nocturno de limpiadores de prótesis con diferentes composiciones químicas sobre la estabilidad del color de los polímeros base de prótesis (DBP). Los cuatro DBP evaluados fueron PEEK (grupo PK), poliamida moldeada por termoinyección (grupo PA), polimetilmetacrilato (PMMA) autopolimerizado (grupo AP) y resina PMMA termopolimerizada (grupo HP). Los agentes de limpieza utilizados fueron Corega (CT), Protefix (PT) y la solución de hipoclorito de sodio (NaOCl) al 0,5% (SH). El agua destilada (DW) sirvió de control. Se prepararon 48 especímenes en forma de disco (10mm × 2mm) de cada DBP y se sumergieron al azar en los diferentes medios de almacenamiento (n=12 en cada grupo). Las mediciones del color de las muestras antes y después de la inmersión en los limpiadores de dentaduras se realizaron con un espectrofotómetro (VITA Easyshade V). Los cambios de color se midieron y registraron en L* a* b*. Después de 120 d, se utilizó la fórmula CIEDE2000 para calcular los cambios de color (∆E00). Para el análisis de los datos, se utilizó un análisis multivariante de la varianza (p<0,05).  Los resultados del análisis estadístico revelaron diferencias significativas en el cambio de color de los DBP sumergidos en los distintos limpiadores de dentaduras (p<0,05). Los grupos PA y PK mostraron los valores más altos para todas las soluciones. AP-SH mostró el valor ∆E00 más alto en el grupo AP, no se encontraron diferencias significativas entre las demás soluciones. En el grupo HP, no hubo diferencias estadísticamente significativas entre los valores medios de ∆E00 de todas las soluciones. El uso diario a largo plazo de los limpiadores de dentaduras afectó a la estabilidad del color de todos los DBP, aunque el nivel de cambio de color fue aceptable. Se necesitan estudios de laboratorio y clínicos sobre la estabilidad del color del PEEK para confirmar los resultados de este estudio.
title Efecto in vitro de los limpiadores de prótesis en la estabilidad del color de la polieteretercetona y otros polímeros base de prótesis
title_short Efecto in vitro de los limpiadores de prótesis en la estabilidad del color de la polieteretercetona y otros polímeros base de prótesis
title_full Efecto in vitro de los limpiadores de prótesis en la estabilidad del color de la polieteretercetona y otros polímeros base de prótesis
title_fullStr Efecto in vitro de los limpiadores de prótesis en la estabilidad del color de la polieteretercetona y otros polímeros base de prótesis
title_full_unstemmed Efecto in vitro de los limpiadores de prótesis en la estabilidad del color de la polieteretercetona y otros polímeros base de prótesis
title_sort efecto in vitro de los limpiadores de prótesis en la estabilidad del color de la polieteretercetona y otros polímeros base de prótesis
title_alt In Vitro Effect of Denture Cleansers on the Color Stability of Polyetheretherketone and Other Denture Base Polymers
publisher Universidad de Costa Rica
publishDate 2021
url https://revistas.ucr.ac.cr/index.php/Odontos/article/view/47335
work_keys_str_mv AT tekinsamet invitroeffectofdenturecleansersonthecolorstabilityofpolyetheretherketoneandotherdenturebasepolymers
AT tekinsamet efectoinvitrodeloslimpiadoresdeprotesisenlaestabilidaddelcolordelapolieteretercetonayotrospolimerosbasedeprotesis
_version_ 1810113450671603712
spelling ODONTOS473352022-09-13T18:12:43Z In Vitro Effect of Denture Cleansers on the Color Stability of Polyetheretherketone and Other Denture Base Polymers Efecto in vitro de los limpiadores de prótesis en la estabilidad del color de la polieteretercetona y otros polímeros base de prótesis Tekin, Samet Color stability; Denture base material; PEEK; PMMA; Polymer. Estabilidad de color; Material de base para prótesis; PEEK; PMMA; Polímero. The aim of this in vitro study was to compare the long-term effect of overnight use of denture cleansers with different chemical compositions on the color stability of denture base polymers (DBPs). The four DBPs evaluated were PEEK (PK group), thermoinjection-molded polyamide (PA group), auto-polymerized polymethylmethacrylate (PMMA) (AP group), and heat-polymerized resin PMMA (HP group). The cleaning agents used were Corega tablet (CT), Protefix tablet (PT), and 0.5% sodium hypochlorite (NaOCl) solution (SH). Distilled water (DW) served as a control. Forty-eight disc-shaped specimens (10mm × 2mm) were prepared from each DBP and randomly immersed in the different storage media (n=12 in each group). Color measurements of the specimens before and after immersion in the denture cleansers were made using a spectrophotometer (VITA Easyshade V). The color changes were measured and recorded in L* a* b*. After 120 d, the CIEDE2000 formula was used to calculate color changes (∆E00). For analysis of the data, a multivariate analysis of variance was used (p<0.05).  The results of the statistical analysis revealed significant color change differences in the DBPs immersed in the various denture cleansers (p<0.05). Groups PA and PK showed the highest values for all solutions. AP-SH showed the highest ∆E00 value in group AP, no significant difference was found between other solutions. In group HP, there was no statistically significant difference between the average ∆E00 values of all solutions.  Long-term daily use of the denture cleansers affected the color stability of all the DBPs, although the level of color change was acceptable. Laboratory and clinical studies on the color stability of PEEK are needed to confirm the results of this study. El objetivo de este estudio in vitro fue comparar el efecto a largo plazo del uso nocturno de limpiadores de prótesis con diferentes composiciones químicas sobre la estabilidad del color de los polímeros base de prótesis (DBP). Los cuatro DBP evaluados fueron PEEK (grupo PK), poliamida moldeada por termoinyección (grupo PA), polimetilmetacrilato (PMMA) autopolimerizado (grupo AP) y resina PMMA termopolimerizada (grupo HP). Los agentes de limpieza utilizados fueron Corega (CT), Protefix (PT) y la solución de hipoclorito de sodio (NaOCl) al 0,5% (SH). El agua destilada (DW) sirvió de control. Se prepararon 48 especímenes en forma de disco (10mm × 2mm) de cada DBP y se sumergieron al azar en los diferentes medios de almacenamiento (n=12 en cada grupo). Las mediciones del color de las muestras antes y después de la inmersión en los limpiadores de dentaduras se realizaron con un espectrofotómetro (VITA Easyshade V). Los cambios de color se midieron y registraron en L* a* b*. Después de 120 d, se utilizó la fórmula CIEDE2000 para calcular los cambios de color (∆E00). Para el análisis de los datos, se utilizó un análisis multivariante de la varianza (p<0,05).  Los resultados del análisis estadístico revelaron diferencias significativas en el cambio de color de los DBP sumergidos en los distintos limpiadores de dentaduras (p<0,05). Los grupos PA y PK mostraron los valores más altos para todas las soluciones. AP-SH mostró el valor ∆E00 más alto en el grupo AP, no se encontraron diferencias significativas entre las demás soluciones. En el grupo HP, no hubo diferencias estadísticamente significativas entre los valores medios de ∆E00 de todas las soluciones. El uso diario a largo plazo de los limpiadores de dentaduras afectó a la estabilidad del color de todos los DBP, aunque el nivel de cambio de color fue aceptable. Se necesitan estudios de laboratorio y clínicos sobre la estabilidad del color del PEEK para confirmar los resultados de este estudio. Universidad de Costa Rica 2021-06-09 info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Article application/pdf text/html application/epub+zip https://revistas.ucr.ac.cr/index.php/Odontos/article/view/47335 10.15517/ijds.2021.47335 Odovtos - International Journal of Dental Sciences; Vol. 24 No. 2 (2022): (May-August) ODOVTOS-International Journal of Dental Sciences; 47-56 Odovtos International Journal of Dental Sciences; Vol. 24 Núm. 2 (2022): (May-August) ODOVTOS-International Journal of Dental Sciences; 47-56 2215-3411 1659-1046 10.15517/ijds.2022 eng https://revistas.ucr.ac.cr/index.php/Odontos/article/view/47335/46806 https://revistas.ucr.ac.cr/index.php/Odontos/article/view/47335/46807 https://revistas.ucr.ac.cr/index.php/Odontos/article/view/47335/46808 Copyright (c) 2022 CC-BY-NC-SA 4.0