Accuracy and Reliability of Inertial Devices for Load Assessment During Flywheel Workout

Detalles Bibliográficos
Autores principales: Pino-Ortega, Jose, Hernández-Belmonte, Alejandro, Bastida-Castillo, Alejandro, Gómez-Carmona, Carlos, Rojas-Valverde, Daniel
Formato: Online
Idioma:eng
spa
Publicado: Universidad Nacional, Costa Rica 2021
Acceso en línea:https://www.revistas.una.ac.cr/index.php/mhsalud/article/view/13406
id MHSALUD13406
record_format ojs
institution Universidad Nacional de Costa Rica
collection MHSalud: Revista en Ciencias del Movimiento Humano y Salud
language eng
spa
format Online
author Pino-Ortega, Jose
Hernández-Belmonte, Alejandro
Bastida-Castillo, Alejandro
Gómez-Carmona, Carlos
Rojas-Valverde, Daniel
spellingShingle Pino-Ortega, Jose
Hernández-Belmonte, Alejandro
Bastida-Castillo, Alejandro
Gómez-Carmona, Carlos
Rojas-Valverde, Daniel
Accuracy and Reliability of Inertial Devices for Load Assessment During Flywheel Workout
author_facet Pino-Ortega, Jose
Hernández-Belmonte, Alejandro
Bastida-Castillo, Alejandro
Gómez-Carmona, Carlos
Rojas-Valverde, Daniel
author_sort Pino-Ortega, Jose
title Accuracy and Reliability of Inertial Devices for Load Assessment During Flywheel Workout
title_short Accuracy and Reliability of Inertial Devices for Load Assessment During Flywheel Workout
title_full Accuracy and Reliability of Inertial Devices for Load Assessment During Flywheel Workout
title_fullStr Accuracy and Reliability of Inertial Devices for Load Assessment During Flywheel Workout
title_full_unstemmed Accuracy and Reliability of Inertial Devices for Load Assessment During Flywheel Workout
title_sort accuracy and reliability of inertial devices for load assessment during flywheel workout
title_alt Precisión y confiabilidad de los dispositivos inerciales para la evaluación de la carga durante entrenamiento con polea cónica
Precisão e confiabilidade dos dispositivos inerciais para avaliação da carga durante o treinamento com polia cônica
publisher Universidad Nacional, Costa Rica
publishDate 2021
url https://www.revistas.una.ac.cr/index.php/mhsalud/article/view/13406
work_keys_str_mv AT pinoortegajose accuracyandreliabilityofinertialdevicesforloadassessmentduringflywheelworkout
AT hernandezbelmontealejandro accuracyandreliabilityofinertialdevicesforloadassessmentduringflywheelworkout
AT bastidacastilloalejandro accuracyandreliabilityofinertialdevicesforloadassessmentduringflywheelworkout
AT gomezcarmonacarlos accuracyandreliabilityofinertialdevicesforloadassessmentduringflywheelworkout
AT rojasvalverdedaniel accuracyandreliabilityofinertialdevicesforloadassessmentduringflywheelworkout
AT pinoortegajose precisionyconfiabilidaddelosdispositivosinercialesparalaevaluaciondelacargaduranteentrenamientoconpoleaconica
AT hernandezbelmontealejandro precisionyconfiabilidaddelosdispositivosinercialesparalaevaluaciondelacargaduranteentrenamientoconpoleaconica
AT bastidacastilloalejandro precisionyconfiabilidaddelosdispositivosinercialesparalaevaluaciondelacargaduranteentrenamientoconpoleaconica
AT gomezcarmonacarlos precisionyconfiabilidaddelosdispositivosinercialesparalaevaluaciondelacargaduranteentrenamientoconpoleaconica
AT rojasvalverdedaniel precisionyconfiabilidaddelosdispositivosinercialesparalaevaluaciondelacargaduranteentrenamientoconpoleaconica
AT pinoortegajose precisaoeconfiabilidadedosdispositivosinerciaisparaavaliacaodacargaduranteotreinamentocompoliaconica
AT hernandezbelmontealejandro precisaoeconfiabilidadedosdispositivosinerciaisparaavaliacaodacargaduranteotreinamentocompoliaconica
AT bastidacastilloalejandro precisaoeconfiabilidadedosdispositivosinerciaisparaavaliacaodacargaduranteotreinamentocompoliaconica
AT gomezcarmonacarlos precisaoeconfiabilidadedosdispositivosinerciaisparaavaliacaodacargaduranteotreinamentocompoliaconica
AT rojasvalverdedaniel precisaoeconfiabilidadedosdispositivosinerciaisparaavaliacaodacargaduranteotreinamentocompoliaconica
_version_ 1805399824182280192
spelling MHSALUD134062023-09-11T21:46:12Z Accuracy and Reliability of Inertial Devices for Load Assessment During Flywheel Workout Precisión y confiabilidad de los dispositivos inerciales para la evaluación de la carga durante entrenamiento con polea cónica Precisão e confiabilidade dos dispositivos inerciais para avaliação da carga durante o treinamento com polia cônica Pino-Ortega, Jose Hernández-Belmonte, Alejandro Bastida-Castillo, Alejandro Gómez-Carmona, Carlos Rojas-Valverde, Daniel technology weightlifting exercise physical fitness sports tecnología levantamiento de pesas ejercicio aptitud física deportes tecnologia levantamento de pesos exercício aptidão física esportes There is currently an increase in inertial flywheel application in strength training; thus, it must be monitored by an accurate and reliable device. The present study tested: (1) the accuracy of an inertial measurement device (IMU) to correctly measure angular velocity and (2) its inter-unit reliability for the measurement of external load. The analysis was performed using Pearson Correlation and Intraclass Correlation Coefficient (ICC). The IMU accuracy was tested using Bland-Altman and the reliability with the coefficient of variation (CV). Ten elite-level football players performed ten series of 5 repetitions in a one-hand standing row exercise (5 series with each arm). A nearly perfect accuracy (ICC=.999) and a very good between-device reliability (Bias=-.010; CV=.017%) was found. IMU is a reliable and valid device to assess angular velocity in inertial flywheel workout objectively. Actualmente, hay un aumento en la utilización de la polea cónica en el entrenamiento de fuerza; por lo tanto, es necesario monitorearlo con un dispositivo preciso y confiable. El presente estudio probó: (1) la precisión de un dispositivo de medición inercial (IMU), para medir correctamente la velocidad angular y (2) su confiabilidad entre unidades para la medición de carga externa. El análisis se realizó utilizando la correlación de Pearson y el Coeficiente de Correlación Intra-clase (CCI). La precisión de la IMU se probó usando Bland-Altman y la confiabilidad con el Coeficiente de Variación (CV). Diez jugadores de fútbol de nivel élite realizaron 10 series de 5 repeticiones en un ejercicio de fila de pie con una mano (5 series con cada brazo). Se encontró una precisión casi perfecta (ICC = .999) y una muy buena confiabilidad entre dispositivos (Sesgo = -. 010; CV = .017%). IMU´s es un dispositivo confiable y válido para evaluar objetivamente la velocidad angular en el entrenamiento inercial de la polea cónica. Atualmente, há um aumento na utilização da polia cônica no treinamento de força; portanto, é necessário monitorá-lo com um dispositivo preciso e confiável. O presente estudo testou: (1) a precisão de um dispositivo de medição inercial (IMU), para medir corretamente a velocidade angular e (2) sua confiabilidade interunidades para medição de carga externa. A análise foi realizada por meio da correlação de Pearson e do Coeficiente de Correlação Intraclasse (ICC). A precisão do IMU foi testada usando Bland-Altman e a confiabilidade com o Coeficiente de Variação (CV). Dez jogadores de futebol de elite realizaram 10 séries de 5 repetições em um exercício de linha em pé com uma mão (5 séries com cada braço). Foi encontrado uma precisão quase perfeita (ICC = 0,999) e confiabilidade entre dispositivos muito boa (Bias = - 0,010; CV = 0,017%). IMU's é um dispositivo confiável e válido para avaliar objetivamente a velocidade angular no treinamento inercial da polia cônica. Universidad Nacional, Costa Rica 2021-11-24 info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion text application/pdf text/html application/epub+zip application/xml video/mp4 https://www.revistas.una.ac.cr/index.php/mhsalud/article/view/13406 10.15359/mhs.19-1.1 MHSalud: Revista en Ciencias del Movimiento Humano y Salud; Vol. 19 No. 1 (2022): Movimiento Humano y Salud (enero-junio); 1-11 MHSalud: Revista en Ciencias del Movimiento Humano y Salud; Vol. 19 Núm. 1 (2022): Movimiento Humano y Salud (enero-junio); 1-11 MHSalud: Revista en Ciencias del Movimiento Humano y Salud; v. 19 n. 1 (2022): Movimiento Humano y Salud (enero-junio); 1-11 1659-097X eng spa https://www.revistas.una.ac.cr/index.php/mhsalud/article/view/13406/23694 https://www.revistas.una.ac.cr/index.php/mhsalud/article/view/13406/23767 https://www.revistas.una.ac.cr/index.php/mhsalud/article/view/13406/23768 https://www.revistas.una.ac.cr/index.php/mhsalud/article/view/13406/23769 https://www.revistas.una.ac.cr/index.php/mhsalud/article/view/13406/23693 Copyright (c) 2021 MHSalud: Revista en Ciencias del Movimiento Humano y Salud