Análisis biomecánico del pie protésico Bioc-dm2
Walking is one of the aspects directly compromising human wellbeing, as it has a physical and emotional impact in daily life.For this study, we delve into the challenge of improving some walking conditions in a patient suffering lower limb loss, specifically at transtibialor transfemoral levels. Giv...
Autores principales: | , , , , , , |
---|---|
Formato: | Online |
Idioma: | spa |
Publicado: |
Universidad Tecnológica de Panamá, Panamá
2019
|
Acceso en línea: | https://revistas.utp.ac.pa/index.php/id-tecnologico/article/view/2102 |
id |
IDTEC2102 |
---|---|
record_format |
ojs |
spelling |
IDTEC21022022-07-25T15:41:04Z Biomechanical Analysis of a prosthetic foot Bioc-dm2 Análisis biomecánico del pie protésico Bioc-dm2 Martin, Jhon Hernandez Bejarano, Oscar Heli Martínez, Edwin Yamith Parra Piñeros, Luis A. Romero, Jairo Alberto Perez, Fran Eduard Castro, Phillipe Meziat La marcha humana es uno de los aspectos que comprometen directamente el nivel de bienestar del ser humano, además deimpactar de manera emocional y física, también en el cotidiano vivir. Para este estudio nos encontramos inmersos en el reto de poder mejoraralgunas condiciones de la marcha en un paciente que haya sufrido pérdida de miembros inferiores, específicamente a nivel transtibial o transfemoral.Dado que nuestro propósito fue el análisis, diseño y manufactura de un componente protésico de miembro inferior que supla las necesidades propiasy de funcionalidad, es necesario construir un pie con todos los estándares de calidad que constituya todos y cada uno de los movimientos requeridospara formar el complejo patrón fundamental de la marcha; además que pueda soportar el peso fácilmente y el uso cotidiano además de lascaracterísticas físicas de nuestro paciente objeto de estudio. Al realizar la validación física y en la marcha humana, se observa una respuestaadecuada en términos mecánicos, de material de construcción y el dinamismo del componente, evidenciando la adecuada construcción y ensambledel componente. Por otro lado, podemos evidenciar que el diseño y la verificación del componente nos muestra un elemento competitivo, comparadocon los elementos existentes en el mercado; Haciendo necesario la verificación ante Instituto Nacional de Vigilancia de Medicamentos y AlimentosINVIMA, y la puesta en marcha del dispositivo replicador de uso, para la verificación del componente frente a la norma ISO 10328. Walking is one of the aspects directly compromising human wellbeing, as it has a physical and emotional impact in daily life.For this study, we delve into the challenge of improving some walking conditions in a patient suffering lower limb loss, specifically at transtibialor transfemoral levels. Given that our purpose was the analysis, design and manufacture of a lower-limb prosthetic component, which fills the needsfor functionality, it became necessary to build a foot with all the quality standards associated to each and all movements required to form thecomplex fundamental pattern of walking. Besides, this foot should also easily endure weight, daily use and physical characteristics of the patientobject of this study. When performing physical validation and during human walk, a proper response is observed in terms of mechanics, materialsand dynamics of the component, thus making evident proper construction and assembly. On the other hand, it is feasible that design and verificationof the component provided a competitive element, as compared to existing elements currently in the market. The previous situation generated theneed for verification from the National Institute for Medications and Food (INVIMA), as well as the revision of the use replying device, forcomponent verification, in accordance with ISO 10328. Universidad Tecnológica de Panamá, Panamá 2019-01-31 info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion application/pdf text/html https://revistas.utp.ac.pa/index.php/id-tecnologico/article/view/2102 10.33412/idt.v15.1.2102 I+D Tecnológico; Vol. 15 Núm. 1 (2019): Revista de I+D Tecnológico; 80-86 2219-6714 1680-8894 spa https://revistas.utp.ac.pa/index.php/id-tecnologico/article/view/2102/3050 https://revistas.utp.ac.pa/index.php/id-tecnologico/article/view/2102/3537 Derechos de autor 2019 CC BY-NC-SA 4.0 license https://creativecommons.org/licenses/bync- sa/4.0/ |
institution |
Universidad Tecnológica de Panamá |
collection |
I+D Tecnológico |
language |
spa |
format |
Online |
author |
Martin, Jhon Hernandez Bejarano, Oscar Heli Martínez, Edwin Yamith Parra Piñeros, Luis A. Romero, Jairo Alberto Perez, Fran Eduard Castro, Phillipe Meziat |
spellingShingle |
Martin, Jhon Hernandez Bejarano, Oscar Heli Martínez, Edwin Yamith Parra Piñeros, Luis A. Romero, Jairo Alberto Perez, Fran Eduard Castro, Phillipe Meziat Análisis biomecánico del pie protésico Bioc-dm2 |
author_facet |
Martin, Jhon Hernandez Bejarano, Oscar Heli Martínez, Edwin Yamith Parra Piñeros, Luis A. Romero, Jairo Alberto Perez, Fran Eduard Castro, Phillipe Meziat |
author_sort |
Martin, Jhon Hernandez |
description |
Walking is one of the aspects directly compromising human wellbeing, as it has a physical and emotional impact in daily life.For this study, we delve into the challenge of improving some walking conditions in a patient suffering lower limb loss, specifically at transtibialor transfemoral levels. Given that our purpose was the analysis, design and manufacture of a lower-limb prosthetic component, which fills the needsfor functionality, it became necessary to build a foot with all the quality standards associated to each and all movements required to form thecomplex fundamental pattern of walking. Besides, this foot should also easily endure weight, daily use and physical characteristics of the patientobject of this study. When performing physical validation and during human walk, a proper response is observed in terms of mechanics, materialsand dynamics of the component, thus making evident proper construction and assembly. On the other hand, it is feasible that design and verificationof the component provided a competitive element, as compared to existing elements currently in the market. The previous situation generated theneed for verification from the National Institute for Medications and Food (INVIMA), as well as the revision of the use replying device, forcomponent verification, in accordance with ISO 10328. |
title |
Análisis biomecánico del pie protésico Bioc-dm2 |
title_short |
Análisis biomecánico del pie protésico Bioc-dm2 |
title_full |
Análisis biomecánico del pie protésico Bioc-dm2 |
title_fullStr |
Análisis biomecánico del pie protésico Bioc-dm2 |
title_full_unstemmed |
Análisis biomecánico del pie protésico Bioc-dm2 |
title_sort |
análisis biomecánico del pie protésico bioc-dm2 |
title_alt |
Biomechanical Analysis of a prosthetic foot Bioc-dm2 |
publisher |
Universidad Tecnológica de Panamá, Panamá |
publishDate |
2019 |
url |
https://revistas.utp.ac.pa/index.php/id-tecnologico/article/view/2102 |
work_keys_str_mv |
AT martinjhonhernandez biomechanicalanalysisofaprostheticfootbiocdm2 AT bejaranooscarheli biomechanicalanalysisofaprostheticfootbiocdm2 AT martinezedwinyamith biomechanicalanalysisofaprostheticfootbiocdm2 AT parrapinerosluisa biomechanicalanalysisofaprostheticfootbiocdm2 AT romerojairoalberto biomechanicalanalysisofaprostheticfootbiocdm2 AT perezfraneduard biomechanicalanalysisofaprostheticfootbiocdm2 AT castrophillipemeziat biomechanicalanalysisofaprostheticfootbiocdm2 AT martinjhonhernandez analisisbiomecanicodelpieprotesicobiocdm2 AT bejaranooscarheli analisisbiomecanicodelpieprotesicobiocdm2 AT martinezedwinyamith analisisbiomecanicodelpieprotesicobiocdm2 AT parrapinerosluisa analisisbiomecanicodelpieprotesicobiocdm2 AT romerojairoalberto analisisbiomecanicodelpieprotesicobiocdm2 AT perezfraneduard analisisbiomecanicodelpieprotesicobiocdm2 AT castrophillipemeziat analisisbiomecanicodelpieprotesicobiocdm2 |
_version_ |
1811817970773524480 |