Análisis biomecánico del pie protésico Bioc-dm2

Walking is one of the aspects directly compromising human wellbeing, as it has a physical and emotional impact in daily life.For this study, we delve into the challenge of improving some walking conditions in a patient suffering lower limb loss, specifically at transtibialor transfemoral levels. Giv...

Descripción completa

Detalles Bibliográficos
Autores principales: Martin, Jhon Hernandez, Bejarano, Oscar Heli, Martínez, Edwin Yamith, Parra Piñeros, Luis A., Romero, Jairo Alberto, Perez, Fran Eduard, Castro, Phillipe Meziat
Formato: Online
Idioma:spa
Publicado: Universidad Tecnológica de Panamá, Panamá 2019
Acceso en línea:https://revistas.utp.ac.pa/index.php/id-tecnologico/article/view/2102
id IDTEC2102
record_format ojs
spelling IDTEC21022022-07-25T15:41:04Z Biomechanical Analysis of a prosthetic foot Bioc-dm2 Análisis biomecánico del pie protésico Bioc-dm2 Martin, Jhon Hernandez Bejarano, Oscar Heli Martínez, Edwin Yamith Parra Piñeros, Luis A. Romero, Jairo Alberto Perez, Fran Eduard Castro, Phillipe Meziat La marcha humana es uno de los aspectos que comprometen directamente el nivel de bienestar del ser humano, además deimpactar de manera emocional y física, también en el cotidiano vivir. Para este estudio nos encontramos inmersos en el reto de poder mejoraralgunas condiciones de la marcha en un paciente que haya sufrido pérdida de miembros inferiores, específicamente a nivel transtibial o transfemoral.Dado que nuestro propósito fue el análisis, diseño y manufactura de un componente protésico de miembro inferior que supla las necesidades propiasy de funcionalidad, es necesario construir un pie con todos los estándares de calidad que constituya todos y cada uno de los movimientos requeridospara formar el complejo patrón fundamental de la marcha; además que pueda soportar el peso fácilmente y el uso cotidiano además de lascaracterísticas físicas de nuestro paciente objeto de estudio. Al realizar la validación física y en la marcha humana, se observa una respuestaadecuada en términos mecánicos, de material de construcción y el dinamismo del componente, evidenciando la adecuada construcción y ensambledel componente. Por otro lado, podemos evidenciar que el diseño y la verificación del componente nos muestra un elemento competitivo, comparadocon los elementos existentes en el mercado; Haciendo necesario la verificación ante Instituto Nacional de Vigilancia de Medicamentos y AlimentosINVIMA, y la puesta en marcha del dispositivo replicador de uso, para la verificación del componente frente a la norma ISO 10328. Walking is one of the aspects directly compromising human wellbeing, as it has a physical and emotional impact in daily life.For this study, we delve into the challenge of improving some walking conditions in a patient suffering lower limb loss, specifically at transtibialor transfemoral levels. Given that our purpose was the analysis, design and manufacture of a lower-limb prosthetic component, which fills the needsfor functionality, it became necessary to build a foot with all the quality standards associated to each and all movements required to form thecomplex fundamental pattern of walking. Besides, this foot should also easily endure weight, daily use and physical characteristics of the patientobject of this study. When performing physical validation and during human walk, a proper response is observed in terms of mechanics, materialsand dynamics of the component, thus making evident proper construction and assembly. On the other hand, it is feasible that design and verificationof the component provided a competitive element, as compared to existing elements currently in the market. The previous situation generated theneed for verification from the National Institute for Medications and Food (INVIMA), as well as the revision of the use replying device, forcomponent verification, in accordance with ISO 10328. Universidad Tecnológica de Panamá, Panamá 2019-01-31 info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion application/pdf text/html https://revistas.utp.ac.pa/index.php/id-tecnologico/article/view/2102 10.33412/idt.v15.1.2102 I+D Tecnológico; Vol. 15 Núm. 1 (2019): Revista de I+D Tecnológico; 80-86 2219-6714 1680-8894 spa https://revistas.utp.ac.pa/index.php/id-tecnologico/article/view/2102/3050 https://revistas.utp.ac.pa/index.php/id-tecnologico/article/view/2102/3537 Derechos de autor 2019 CC BY-NC-SA 4.0 license https://creativecommons.org/licenses/bync- sa/4.0/
institution Universidad Tecnológica de Panamá
collection I+D Tecnológico
language spa
format Online
author Martin, Jhon Hernandez
Bejarano, Oscar Heli
Martínez, Edwin Yamith
Parra Piñeros, Luis A.
Romero, Jairo Alberto
Perez, Fran Eduard
Castro, Phillipe Meziat
spellingShingle Martin, Jhon Hernandez
Bejarano, Oscar Heli
Martínez, Edwin Yamith
Parra Piñeros, Luis A.
Romero, Jairo Alberto
Perez, Fran Eduard
Castro, Phillipe Meziat
Análisis biomecánico del pie protésico Bioc-dm2
author_facet Martin, Jhon Hernandez
Bejarano, Oscar Heli
Martínez, Edwin Yamith
Parra Piñeros, Luis A.
Romero, Jairo Alberto
Perez, Fran Eduard
Castro, Phillipe Meziat
author_sort Martin, Jhon Hernandez
description Walking is one of the aspects directly compromising human wellbeing, as it has a physical and emotional impact in daily life.For this study, we delve into the challenge of improving some walking conditions in a patient suffering lower limb loss, specifically at transtibialor transfemoral levels. Given that our purpose was the analysis, design and manufacture of a lower-limb prosthetic component, which fills the needsfor functionality, it became necessary to build a foot with all the quality standards associated to each and all movements required to form thecomplex fundamental pattern of walking. Besides, this foot should also easily endure weight, daily use and physical characteristics of the patientobject of this study. When performing physical validation and during human walk, a proper response is observed in terms of mechanics, materialsand dynamics of the component, thus making evident proper construction and assembly. On the other hand, it is feasible that design and verificationof the component provided a competitive element, as compared to existing elements currently in the market. The previous situation generated theneed for verification from the National Institute for Medications and Food (INVIMA), as well as the revision of the use replying device, forcomponent verification, in accordance with ISO 10328.
title Análisis biomecánico del pie protésico Bioc-dm2
title_short Análisis biomecánico del pie protésico Bioc-dm2
title_full Análisis biomecánico del pie protésico Bioc-dm2
title_fullStr Análisis biomecánico del pie protésico Bioc-dm2
title_full_unstemmed Análisis biomecánico del pie protésico Bioc-dm2
title_sort análisis biomecánico del pie protésico bioc-dm2
title_alt Biomechanical Analysis of a prosthetic foot Bioc-dm2
publisher Universidad Tecnológica de Panamá, Panamá
publishDate 2019
url https://revistas.utp.ac.pa/index.php/id-tecnologico/article/view/2102
work_keys_str_mv AT martinjhonhernandez biomechanicalanalysisofaprostheticfootbiocdm2
AT bejaranooscarheli biomechanicalanalysisofaprostheticfootbiocdm2
AT martinezedwinyamith biomechanicalanalysisofaprostheticfootbiocdm2
AT parrapinerosluisa biomechanicalanalysisofaprostheticfootbiocdm2
AT romerojairoalberto biomechanicalanalysisofaprostheticfootbiocdm2
AT perezfraneduard biomechanicalanalysisofaprostheticfootbiocdm2
AT castrophillipemeziat biomechanicalanalysisofaprostheticfootbiocdm2
AT martinjhonhernandez analisisbiomecanicodelpieprotesicobiocdm2
AT bejaranooscarheli analisisbiomecanicodelpieprotesicobiocdm2
AT martinezedwinyamith analisisbiomecanicodelpieprotesicobiocdm2
AT parrapinerosluisa analisisbiomecanicodelpieprotesicobiocdm2
AT romerojairoalberto analisisbiomecanicodelpieprotesicobiocdm2
AT perezfraneduard analisisbiomecanicodelpieprotesicobiocdm2
AT castrophillipemeziat analisisbiomecanicodelpieprotesicobiocdm2
_version_ 1811817970773524480